Tuesday, May 7, 2013

OSI145 - Overcentre Valve (180 lpm)



Application
Overcentre valves give static and dynamic control of loads by regulating flow into and out of hydraulic actuators. The Overcentre valve will stop the load from running away in the event of a hose burst. If open centre directional control valves are used, they will allow the thermal expansion relief of the hydraulic fluid. These valves provide excellent hose burst protection.


Operation
The check section allows free flow into the actuator then holds and locks the load against movement. The pilot pressure in the pilot port will give a controlled movement to piston when the pressure is applied. The pressure required to open the valve and allow movement depends on the pilot ratio of the valve.


Specifications
Max. Flow 180 lpm
Max. Pressure 350 bar
Weight (Cartridge) 1.20 kgs
Body Aluminium/SG Iron
Ports 3/4", 1" BSP
Leakage 0.3 milliliters/min (5 dpm)